POCUS Tips › Setup

Before You ScanSETUP

Sixty seconds of setup buys you a diagnostic image. Probe, preset, depth, gain — in that order, every time.

Open the interactive view with the loop and quiz →

The sixty-second setup

  1. Pick the probe for the depth you need, then select the matching preset — the preset changes the frame rate and the orientation convention.
  2. Confirm orientation before you interpret anything: tap the marker side of the probe and watch which edge of the screen brightens.
  3. Set depth so the structure of interest fills the lower two-thirds, then set gain so fluid is black and tissue is gray.
  4. Freeze, scroll back through the cine loop, and measure on the best frame — never on the live image.

Probe selection

ProbeFrequencyReach for it when
Phased arraysmall footprint, wide sector1–5 MHzheart, IVC, and lung when you need depth — fits between ribs
Curvilinearlarge footprint, wide field2–5 MHzabdomen, pleural effusion, deep structures in larger patients
Linearflat footprint, high resolution5–15 MHzpleural line, vessels, soft tissue, procedures
Preset matterscardiac vs abdominalorientation flipscardiac puts the marker on screen right; abdominal puts it on screen left

Don’t be fooled — pitfalls

Bad image? Fix it

So what — what the finding changes

Keep going

Educational use only. Not for diagnosis or treatment decisions — confirm findings with formal imaging and your own judgment. By Yonathan Daniel, MD · Pathways · Quiz on this view · About · Last reviewed 2026-10-04.